Vue de la page 30
CR Carriage return
[ASCII] CR
[Decimal] 13
[Hexadecimal] 0D
[Parameters] None
[Description]
Concludes the input of one line, and waits for input of the second line.
A “Line Feed” command after “Carriage return” command is ignored.
ESC D Specify horizontal tab position
[ASCII] ESC D [n]
k
NUL
[Decimal] 27 68 [n]
k
0
[Hexadecimal] 1B 44 [n]
k
00h
[Parameters] 1 n 255
0 k 32
[Description]
The horizontal tab position is set at the position of the character width when the horizontal tab
is specified *n from the left margin position.
Enter n in ascending order, and end the setting with NUL.
If any n value is smaller than the value before it, the tab setting is finished.
HT Apply horizontal tab
[ASCII] HT
[Decimal] 9
[Hexadecimal] 09
[Parameters] None
31
[Description]
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Unprinted area
HT code
Left side Left margin position Right margin position
Printable area
Example: After setting left margin=column 3 and right margin=column 15,
set horizontal tabs at columns 5 and 10, and perform an HT
Column
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Tab position Tab position
HT code
Unprinted area
Vue de la page 30